MCP ScannerCustom audit
All servers

Lavaxzyh/ads-mcp

Open-source MCP server for Keysight ADS — 49 tools for schematic → native Layout → Momentum → emModel cosimulation, parameterized EM optimization, and vendor model integration.

PublisherLavaxzyh community
MCP Registrynot listed
Scanned2026-11-25
Scannerv1.3.0
Methodologyv1.2
Stars 29Forks 2Last push 2026-11-13
Python 97.4%JavaScript 2.6%by source files the scanner reads
Code safetypartly tracedExposure5.1Prompts10.0Supply chainnot checkedSecrets10.0Transparency10.0
Analysis confidence97%
How much of the server the scanner could read: tools analyzed, files parsed, limits hit.
Code Safetypartly traced—

Paths from tool input into commands, SQL, files and URLs

Capability Exposure5.1/10Fair

How much power the tools give an agent over the machine

Prompt Integritynothing published yet10.0/10

Hidden instructions and poisoning in text for the model

Supply Chainnot checked—

Known vulnerabilities in the packages the server uses

Secrets & Credentialsnothing published yet10.0/10

How the server reads credentials and where they can go

Behavior Transparencynothing published yet10.0/10

Whether the tools do only what their descriptions say

How far the analysis went

The scanner traces each tool from its input to the operations its code performs, and here it could not follow every path. Code Safety is shown as partly traced instead of a score: no finding there is not a clean result. The score of Capability Exposure counts only what it could follow.

  • In 19 places a tool's input is handed to a function whose name matches several definitions in the code; the scanner could not tell which one runs, so it stopped there
  • Supply Chain: no dependency file the scanner reads was found, so it has no number

Top risks in plain words

  • HIGHTools ads_export_touchstone, ads_run_simulation read or write any file path by design: an agent steered by prompt injection can use them that way.

How to use it safely

Practical steps from what we found in this server. They lower the risk; they do not replace a review of the code.

  • Give it only the folder it needs

    ads_export_touchstone, ads_run_simulation can read or write any file path. Mount a single project folder, read-only where you can.

  • Turn off the tools you do not use

    Most MCP clients let you disable single tools. If you do not need ads_export_touchstone, ads_run_simulation, switch them off.

  • Give it a narrowly scoped token

    Its code reads credentials or environment variables. Use a key limited to what this server needs, not your main one.

  • Keep confirmations on

    Leave your MCP client's confirmation prompt on for tools that change files, run commands or send data.

What its tools can do on your machine

The server offers 49 tools. When an AI agent calls them, this is what their code can do on the machine where the server runs, as traced in the source. Tools that call code the scanner could not follow may do more.

Read or write filesopen, create, change or delete files
ads_add_design_port, ads_add_goal, ads_add_ground, ads_add_optim, ads_add_term, ads_add_var and 32 more
38 of 49
Read environment variablesoften where API keys are kept
ads_add_design_port, ads_add_goal, ads_add_ground, ads_add_optim, ads_add_var, ads_add_wire and 29 more
35 of 49

No tool was seen to: start other programs on the machine; connect to the internet or other hosts; read passwords, tokens or keys; touch sensitive locations.

Where its requests and secrets go

Read from the names along each tool's calls, not from a run: what the code says, not every address it may reach at run time.

Hosts written in the code

The literal addresses the tools' requests name.

  • None: no request names a fixed host.
Addresses from settings

Constants or settings that start an address; the value comes from configuration.

  • None seen.
Secrets it reads

Credential-like environment variables. Give the server a key with the least access it needs.

  • None: no credential-like variable is read by the tools.

Text it brings in from outside

Text that reaches the model from outside: an instruction hidden in it can steer the agent (prompt injection). Treat what these tools return as data, not as orders.

  • files38 tools · ads_add_design_port, ads_add_goal, ads_add_ground +35

Tool annotations

No tool declares MCP annotations (readOnlyHint, destructiveHint and the rest). Clients use them to decide what to confirm; directories such as Anthropic's and OpenAI's ask for them.

Tools, prompts and resources (49: 49 tools)

Open a row for its full description. Chips show what its code can reach, and which risky capability its own description declares.

ads_export_touchstonetool Export the full 1/N-port matrix to a matching .sNp file (50-ohm reference).Filesoutside textReads/writes files
Export the full 1/N-port matrix to a matching .sNp file (50-ohm reference).
ads_run_simulationtool Save the schematic, netlist it, and run hpeesofsim in the background.FilesEnv varsoutside textReads/writes files
Save the schematic, netlist it, and run hpeesofsim in the background.

    Returns a `task_id`; poll with ads_get_sim_status.  The result carries the
    dataset path for ads_get_results / ads_plot_sparams / ads_export_touchstone.
ads_add_design_porttool Add a Subnetwork terminal on a specified instance pin and its actual net (not a simulation TermG).FilesEnv varsoutside text
Add a Subnetwork terminal on a specified instance pin and its actual net (not a simulation TermG).
ads_add_goaltool Add an optimization goal (ads_simulation:Goal).FilesEnv varsoutside text
Add an optimization goal (ads_simulation:Goal).

    goal_type 'min' keeps `expr` at or above `bound` (e.g. passband S21);
    'max' keeps it at or below `bound` (e.g. stopband rejection, return loss
    limit). `expr` like "dB(S(1,2))", `sim_name` is the analysis controller
    name (e.g. "SP1"), fmin/fmax bracket the evaluation band.
ads_add_groundtool Place a ground symbol at (x, y).FilesEnv varsoutside text
Place a ground symbol at (x, y).
ads_add_layout_portstool Add numbered point pins to an existing saved layout in this workspace.
Add numbered point pins to an existing saved layout in this workspace.

    Each pin specifies name, number, x_mm, y_mm, optional angle, layer and
    net. Names and numbers must be distinct, including existing terminals.
    For Momentum, use consecutive terminal numbers starting at 1. Port
    impedance/reference mapping is created by ads_configure_momentum_setup.
ads_add_optimtool Place the optimization controller (ads_simulation:Optim).FilesEnv varsoutside text
Place the optimization controller (ads_simulation:Optim).

    It automatically collects every variable that has an opt range and every
    goal on the schematic. optim_type: gradient / random / quasinewton.
ads_add_termtool Place an S-parameter port (Term) with its ground; name like Term1/Term2.Filesoutside text
Place an S-parameter port (Term) with its ground; name like Term1/Term2.
ads_add_vartool Define a schematic variable in the VAR block, e.g. ("W_hi", "0.3 mm").FilesEnv varsoutside text
Define a schematic variable in the VAR block, e.g. ("W_hi", "0.3 mm").

    Component parameters can then reference the name (e.g. W="W_hi").
    Optional opt_min/opt_max turn it into an optimization variable
    (e.g. opt_min="0.5 mm", opt_max="1.4 mm").
ads_add_wiretool Add a polyline wire through `points` [[x1,y1],[x2,y2],...]; optional net label.FilesEnv varsoutside text
Add a polyline wire through `points` [[x1,y1],[x2,y2],...]; optional net label.
ads_arrange_windowstool Tile via setGeometry, maximize each selected window, or restore tool-saved states; never closes windows.FilesEnv varsoutside text
Tile via setGeometry, maximize each selected window, or restore tool-saved states; never closes windows.
ads_audit_schematictool Audit a schematic for overlapping elements (KiCad-style).FilesEnv varsoutside text
Audit a schematic for overlapping elements (KiCad-style).

    Compares every pair of instance bounding boxes (body vs annotation text)
    and reports collisions by severity: body-body / body-text / text-text.
    With lib+cell, audits the SAVED design read-only; without, audits the
    current in-memory design. Aim for zero body-level collisions before
    delivering a schematic.
ads_autolabeltool Auto-place instance labels to clear text-level collisions (KiCad-style).FilesEnv varsoutside text
Auto-place instance labels to clear text-level collisions (KiCad-style).

    For each text collision, tries four candidate sides for the later
    instance's annotation and moves it to the first collision-free spot.
    Body-body collisions are reported only — fix those in the layout.
ads_browse_componentstool List component libraries and cells (with known parameter names).Env vars
List component libraries and cells (with known parameter names).

    Call without `lib` to enumerate all standard libraries; with `lib` to list
    that library's cells.  Microstrip parts live in `ads_tlines`, controllers
    and ports in `ads_simulation`, VAR/MeasEqn in `ads_datacmps`.
ads_check_installedtool Check ADS install, simulator binary, and the headless DE engine.Env vars
Check ADS install, simulator binary, and the headless DE engine.
ads_close_workspacetool Close the currently open workspace.FilesEnv varsoutside text
Close the currently open workspace.
ads_compare_sparameterstool Compare all complex N-port S terms on equal frequency grids without interpolation.Filesoutside text
Compare all complex N-port S terms on equal frequency grids without interpolation.
ads_configure_em_modeltool Configure native auto-create/update output. Reload workspace then run Momentum to create model data.FilesEnv varsoutside text
Configure native auto-create/update output. Reload workspace then run Momentum to create model data.
ads_configure_em_parameterstool Set native model geometry cache interpolation/resolution; does not clear samples or simulate.FilesEnv varsoutside text
Set native model geometry cache interpolation/resolution; does not clear samples or simulate.
ads_configure_momentum_meshtool Configure global cells/wavelength, edge mesh and reference frequency. Requires reload and a new solve.FilesEnv varsoutside text
Configure global cells/wavelength, edge mesh and reference frequency. Requires reload and a new solve.
ads_configure_momentum_optionstool Extend an existing Setup with direct linear RF/DC plans and Auto/TML/uncalibrated internal ports.FilesEnv varsoutside text
Extend an existing Setup with direct linear RF/DC plans and Auto/TML/uncalibrated internal ports.
ads_configure_momentum_setuptool Create/link a native Momentum setup from the local ADS RFBoard template.
Create/link a native Momentum setup from the local ADS RFBoard template.

    Uses existing local layout and substrate, a single linear frequency sweep,
    microwave mode, local execution, fresh results and numbered single-pin 50-ohm ground-
    referenced ports with a bottom ground cover. The installed vendor template
    is read at runtime; none is distributed. Existing setup names are rejected
    to retain prior setups.
    The native dataset uses the cell name; completed tasks retain unique
    copies. The returned setup_file can be passed to ads_run_momentum after
    closing the server workspace and opening the saved workspace in ADS GUI.
ads_create_layouttool Create and save a planar layout from parameterized rectangles/polygons.
Create and save a planar layout from parameterized rectangles/polygons.

    Each shape specifies kind, points_mm and an existing drawing layer name.
    A rectangle has lower-left/upper-right corners; polygons have distinct
    vertices without a repeated closing point. Coordinates are millimeters
    and converted to the library's layout units. Existing views are rejected.
    This accepts explicit geometry; it does not infer arbitrary schematic or
    PDK artwork. Use ads_add_layout_ports after creation.
ads_create_librarytool Create a design library inside the open workspace and attach it.FilesEnv varsoutside text
Create a design library inside the open workspace and attach it.
ads_create_schematictool Create (or open) a schematic cell `lib:cell` as the current design.FilesEnv varsoutside text
Create (or open) a schematic cell `lib:cell` as the current design.
ads_create_substratetool Create a parameterized planar substrate in the current local library.
Create a parameterized planar substrate in the current local library.

    dielectrics are bottom-to-top, with height_mm, er and loss_tangent.
    conductors map existing drawing layer names to interface 1..N above N
    dielectrics, with thickness_um and optional conductivity_s_per_m (null =
    perfect conductor). Bottom ground is an ideal cover when enabled; top is
    open air. A new substrate name is required; existing substrates/materials
    are preserved. New libraries receive standard ADS layout technology.
ads_create_workspacetool Create (or open if existing) an ADS workspace at `path` and open it.FilesEnv varsoutside text
Create (or open if existing) an ADS workspace at `path` and open it.
ads_define_cell_parameterstool Persist REAL, NO_UNIT Subnetwork formal parameters in itemdef.py. Use W*1 mm in artwork.FilesEnv varsoutside text
Persist REAL, NO_UNIT Subnetwork formal parameters in itemdef.py. Use W*1 mm in artwork.
ads_generate_layouttool Generate native artwork from a saved schematic via update_design_from; optionally make a PSN PCell.FilesEnv varsoutside text
Generate native artwork from a saved schematic via update_design_from; optionally make a PSN PCell.
ads_generate_netlisttool Generate the netlist of the current schematic and return its text.FilesEnv varsoutside text
Generate the netlist of the current schematic and return its text.
ads_generate_symboltool Generate a rectangular Dual/Quad or native Layout-lookalike symbol. Does not generate EM data.FilesEnv varsoutside text
Generate a rectangular Dual/Quad or native Layout-lookalike symbol. Does not generate EM data.
ads_get_resultstool Read a simulation dataset (.ds): S-parameter summary and data preview.Filesoutside text
Read a simulation dataset (.ds): S-parameter summary and data preview.
ads_get_sim_statustool Poll circuit or Momentum tasks. Momentum reports live frequency progress.
Poll circuit or Momentum tasks. Momentum reports live frequency progress.

    Momentum monitoring survives server restarts; polling does not relaunch
    the solver. A bridge timeout is uncertain dispatch, never a retry signal.
ads_import_librarytool Register a local vendor lib.defs. Reports reload required; does not download or modify vendor models.FilesEnv varsoutside text
Register a local vendor lib.defs. Reports reload required; does not download or modify vendor models.
ads_inspect_em_modeltool Inspect native files, geometry parameter names, sample cache and interpolation policy.FilesEnv varsoutside text
Inspect native files, geometry parameter names, sample cache and interpolation policy.
ads_inspect_momentum_setuptool Inspect a saved native Momentum setup, its layout, paths and linear sweep.
Inspect a saved native Momentum setup, its layout, paths and linear sweep.

    setup_file is the canonical emStateFile.xml inside the EM Setup cellview,
    not the generated copy under simulation/. Requires an existing local
    library and saved layout, native calculation type 5 and one linear sweep
    (verified on ADS 2027). Reports stale copied workspace references; no edits.
ads_list_gui_sessionstool Discover running ADS GUI sessions through installed Keysight ads-mcp.exe.
Discover running ADS GUI sessions through installed Keysight ads-mcp.exe.

    Returns session IDs and workspace paths. Does not start or close ADS.
ads_list_instancestool List instances placed on the current schematic.FilesEnv varsoutside text
List instances placed on the current schematic.
ads_list_windowstool List ADS process windows, design identities, screen bounds and Qt logical-pixel geometry.FilesEnv varsoutside text
List ADS process windows, design identities, screen bounds and Qt logical-pixel geometry.
ads_open_designtool Inspect an existing local design; optionally show it in its ADS GUI session.FilesEnv varsoutside text
Inspect an existing local design; optionally show it in its ADS GUI session.
ads_open_in_guitool Open the current or explicitly specified saved workspace in ADS GUI.FilesEnv varsoutside text
Open the current or explicitly specified saved workspace in ADS GUI.

    The GUI process is detached from this server, so it survives MCP restarts.
    For EM handoff, close the server workspace first, then pass its saved path
    explicitly; the GUI loads the newly created substrate materials on open.
ads_open_workspacetool Open an existing ADS workspace.FilesEnv varsoutside text
Open an existing ADS workspace.
ads_place_componenttool Place a component instance on the current schematic.FilesEnv varsoutside text
Place a component instance on the current schematic.

    `params` maps parameter names to value strings with units, e.g.
    {"W": "0.3 mm", "L": "20 mm"} for ads_tlines:MLIN or {"Er": "4.4"} for
    MSUB.  The substrate (MSUB) is auto-named MSub1; never set its `Subst`
    references on lines - the default already points at MSub1.
ads_plot_sparamstool Plot |S| in dB vs frequency to a PNG (e.g. columns ["S[1,1]", "S[1,2]"]).Filesoutside text
Plot |S| in dB vs frequency to a PNG (e.g. columns ["S[1,1]", "S[1,2]"]).
ads_release_optimizertool Release the simulator of a completed GUI Optim task, retaining its recorded best values without applying them.FilesEnv varsoutside text
Release the simulator of a completed GUI Optim task, retaining its recorded best values without applying them.
ads_run_momentumtool Run an existing native Momentum setup in the selected ADS GUI session.
Run an existing native Momentum setup in the selected ADS GUI session.

    Open the requested workspace in that GUI first. Close any workspace
    owned by this server with ads_close_workspace. The tool verifies the GUI
    workspace/library/setup link, returns task_id, and never closes ADS or
    silently switches workspaces. Poll ads_get_sim_status for fresh outputs
    and configured frequency-grid validation. Saved setups can be created by
    ads_configure_momentum_setup. A reservation prevents duplicate dispatches.
ads_session_statustool Return session state: open workspace, current schematic, task history.
Return session state: open workspace, current schematic, task history.
ads_set_instance_parameterstool Edit existing parameters and explicitly select an existing DUT simulation view.FilesEnv varsoutside text
Edit existing parameters and explicitly select an existing DUT simulation view.
ads_set_mesh_visibilitytool Load/clear native Momentum mesh display objects in one Layout window; does not save the design.FilesEnv varsoutside text
Load/clear native Momentum mesh display objects in one Layout window; does not save the design.

Text the model reads (49)

Every tool, prompt and resource description as written in the code: the model sees all of it, the user usually does not.

ads_check_installed tool
Check ADS install, simulator binary, and the headless DE engine.
ads_create_workspace tool
Create (or open if existing) an ADS workspace at `path` and open it.
ads_open_workspace tool
Open an existing ADS workspace.
ads_close_workspace tool
Close the currently open workspace.
ads_session_status tool
Return session state: open workspace, current schematic, task history.
ads_create_library tool
Create a design library inside the open workspace and attach it.
ads_create_schematic tool
Create (or open) a schematic cell `lib:cell` as the current design.
ads_browse_components tool
List component libraries and cells (with known parameter names).

    Call without `lib` to enumerate all standard libraries; with `lib` to list
    that library's cells.  Microstrip parts live in `ads_tlines`, controllers
    and ports in `ads_simulation`, VAR/MeasEqn in `ads_datacmps`.
ads_place_component tool
Place a component instance on the current schematic.

    `params` maps parameter names to value strings with units, e.g.
    {"W": "0.3 mm", "L": "20 mm"} for ads_tlines:MLIN or {"Er": "4.4"} for
    MSUB.  The substrate (MSUB) is auto-named MSub1; never set its `Subst`
    references on lines - the default already points at MSub1.
ads_add_wire tool
Add a polyline wire through `points` [[x1,y1],[x2,y2],...]; optional net label.
ads_add_var tool
Define a schematic variable in the VAR block, e.g. ("W_hi", "0.3 mm").

    Component parameters can then reference the name (e.g. W="W_hi").
    Optional opt_min/opt_max turn it into an optimization variable
    (e.g. opt_min="0.5 mm", opt_max="1.4 mm").
ads_add_goal tool
Add an optimization goal (ads_simulation:Goal).

    goal_type 'min' keeps `expr` at or above `bound` (e.g. passband S21);
    'max' keeps it at or below `bound` (e.g. stopband rejection, return loss
    limit). `expr` like "dB(S(1,2))", `sim_name` is the analysis controller
    name (e.g. "SP1"), fmin/fmax bracket the evaluation band.
ads_add_optim tool
Place the optimization controller (ads_simulation:Optim).

    It automatically collects every variable that has an opt range and every
    goal on the schematic. optim_type: gradient / random / quasinewton.
ads_add_term tool
Place an S-parameter port (Term) with its ground; name like Term1/Term2.
ads_add_ground tool
Place a ground symbol at (x, y).
ads_list_instances tool
List instances placed on the current schematic.
ads_generate_netlist tool
Generate the netlist of the current schematic and return its text.
ads_run_simulation tool
Save the schematic, netlist it, and run hpeesofsim in the background.

    Returns a `task_id`; poll with ads_get_sim_status.  The result carries the
    dataset path for ads_get_results / ads_plot_sparams / ads_export_touchstone.
ads_get_sim_status tool
Poll circuit or Momentum tasks. Momentum reports live frequency progress.

    Momentum monitoring survives server restarts; polling does not relaunch
    the solver. A bridge timeout is uncertain dispatch, never a retry signal.
ads_list_gui_sessions tool
Discover running ADS GUI sessions through installed Keysight ads-mcp.exe.

    Returns session IDs and workspace paths. Does not start or close ADS.
ads_create_substrate tool
Create a parameterized planar substrate in the current local library.

    dielectrics are bottom-to-top, with height_mm, er and loss_tangent.
    conductors map existing drawing layer names to interface 1..N above N
    dielectrics, with thickness_um and optional conductivity_s_per_m (null =
    perfect conductor). Bottom ground is an ideal cover when enabled; top is
    open air. A new substrate name is required; existing substrates/materials
    are preserved. New libraries receive standard ADS layout technology.
ads_create_layout tool
Create and save a planar layout from parameterized rectangles/polygons.

    Each shape specifies kind, points_mm and an existing drawing layer name.
    A rectangle has lower-left/upper-right corners; polygons have distinct
    vertices without a repeated closing point. Coordinates are millimeters
    and converted to the library's layout units. Existing views are rejected.
    This accepts explicit geometry; it does not infer arbitrary schematic or
    PDK artwork. Use ads_add_layout_ports after creation.
ads_add_layout_ports tool
Add numbered point pins to an existing saved layout in this workspace.

    Each pin specifies name, number, x_mm, y_mm, optional angle, layer and
    net. Names and numbers must be distinct, including existing terminals.
    For Momentum, use consecutive terminal numbers starting at 1. Port
    impedance/reference mapping is created by ads_configure_momentum_setup.
ads_configure_momentum_setup tool
Create/link a native Momentum setup from the local ADS RFBoard template.

    Uses existing local layout and substrate, a single linear frequency sweep,
    microwave mode, local execution, fresh results and numbered single-pin 50-ohm ground-
    referenced ports with a bottom ground cover. The installed vendor template
    is read at runtime; none is distributed. Existing setup names are rejected
    to retain prior setups.
    The native dataset uses the cell name; completed tasks retain unique
    copies. The returned setup_file can be passed to ads_run_momentum after
    closing the server workspace and opening the saved workspace in ADS GUI.
ads_inspect_momentum_setup tool
Inspect a saved native Momentum setup, its layout, paths and linear sweep.

    setup_file is the canonical emStateFile.xml inside the EM Setup cellview,
    not the generated copy under simulation/. Requires an existing local
    library and saved layout, native calculation type 5 and one linear sweep
    (verified on ADS 2027). Reports stale copied workspace references; no edits.
ads_run_momentum tool
Run an existing native Momentum setup in the selected ADS GUI session.

    Open the requested workspace in that GUI first. Close any workspace
    owned by this server with ads_close_workspace. The tool verifies the GUI
    workspace/library/setup link, returns task_id, and never closes ADS or
    silently switches workspaces. Poll ads_get_sim_status for fresh outputs
    and configured frequency-grid validation. Saved setups can be created by
    ads_configure_momentum_setup. A reservation prevents duplicate dispatches.
ads_get_results tool
Read a simulation dataset (.ds): S-parameter summary and data preview.
ads_export_touchstone tool
Export the full 1/N-port matrix to a matching .sNp file (50-ohm reference).
ads_plot_sparams tool
Plot |S| in dB vs frequency to a PNG (e.g. columns ["S[1,1]", "S[1,2]"]).
ads_autolabel tool
Auto-place instance labels to clear text-level collisions (KiCad-style).

    For each text collision, tries four candidate sides for the later
    instance's annotation and moves it to the first collision-free spot.
    Body-body collisions are reported only — fix those in the layout.
ads_audit_schematic tool
Audit a schematic for overlapping elements (KiCad-style).

    Compares every pair of instance bounding boxes (body vs annotation text)
    and reports collisions by severity: body-body / body-text / text-text.
    With lib+cell, audits the SAVED design read-only; without, audits the
    current in-memory design. Aim for zero body-level collisions before
    delivering a schematic.
ads_open_in_gui tool
Open the current or explicitly specified saved workspace in ADS GUI.

    The GUI process is detached from this server, so it survives MCP restarts.
    For EM handoff, close the server workspace first, then pass its saved path
    explicitly; the GUI loads the newly created substrate materials on open.
ads_open_design tool
Inspect an existing local design; optionally show it in its ADS GUI session.
ads_add_design_port tool
Add a Subnetwork terminal on a specified instance pin and its actual net (not a simulation TermG).
ads_set_instance_parameters tool
Edit existing parameters and explicitly select an existing DUT simulation view.
ads_define_cell_parameters tool
Persist REAL, NO_UNIT Subnetwork formal parameters in itemdef.py. Use W*1 mm in artwork.
ads_generate_layout tool
Generate native artwork from a saved schematic via update_design_from; optionally make a PSN PCell.
ads_generate_symbol tool
Generate a rectangular Dual/Quad or native Layout-lookalike symbol. Does not generate EM data.
ads_import_library tool
Register a local vendor lib.defs. Reports reload required; does not download or modify vendor models.
ads_configure_em_model tool
Configure native auto-create/update output. Reload workspace then run Momentum to create model data.
ads_inspect_em_model tool
Inspect native files, geometry parameter names, sample cache and interpolation policy.
ads_configure_em_parameters tool
Set native model geometry cache interpolation/resolution; does not clear samples or simulate.
ads_release_optimizer tool
Release the simulator of a completed GUI Optim task, retaining its recorded best values without applying them.
ads_configure_momentum_mesh tool
Configure global cells/wavelength, edge mesh and reference frequency. Requires reload and a new solve.
ads_configure_momentum_options tool
Extend an existing Setup with direct linear RF/DC plans and Auto/TML/uncalibrated internal ports.
ads_list_windows tool
List ADS process windows, design identities, screen bounds and Qt logical-pixel geometry.
ads_arrange_windows tool
Tile via setGeometry, maximize each selected window, or restore tool-saved states; never closes windows.
ads_set_mesh_visibility tool
Load/clear native Momentum mesh display objects in one Layout window; does not save the design.
ads_compare_sparameters tool
Compare all complex N-port S terms on equal frequency grids without interpolation.

What we checked

The same checks run on every server. Each line below has one of these marks:

FoundA published issue such as a risky tool or a CVE
PassedWe ran the check on this server and found nothing
After reviewChecked; we publish it once a person verifies it
Partly tracedRan, but the scanner could not follow every path to its end
FactWhat the code does, not a judgement either way
Not checkedThe scanner had nothing to read for it, or it needs the live server
Code Safetypartly traced
  • 8 checks: command injection, argument injection, path traversal, server-side request forgery, SQL injection, code execution, unsafe deserialization, template injection
    Checked on every scan. Results in this category are published only after a person has verified them.
Capability Exposure5.1
  • Runs programs the caller chooses
    No tool runs a command or program the caller supplies — 49 tool handlers traced. Not every path could be followed, so this is not a clean pass.
  • Executes caller-supplied code
    No tool evaluates code the caller supplies — 49 tool handlers traced. Not every path could be followed, so this is not a clean pass.
  • Reads or writes any file path MEDIUM
    2 findings in ads_run_simulation; 2 more to review
  • Requests any address
    No tool sends a request to an address the caller supplies — 49 tool handlers traced. Not every path could be followed, so this is not a clean pass.
  • Runs caller-supplied SQL
    No tool executes a query the caller supplies — 49 tool handlers traced. Not every path could be followed, so this is not a clean pass.
  • Tools that start processes
    Not seen in the traced code of 49 capabilities; 49 more call code the scanner could not follow, where it may happen
  • Tools that touch files
    38 of 49 capabilities touch files; 11 more call code the scanner could not follow, where it may happen
  • Tools that call the network
    Not seen in the traced code of 49 capabilities; 49 more call code the scanner could not follow, where it may happen
Where the code is: 49 handlers in 2 files at commit a9ac2daaae5c
Prompt Integrity10.0
  • 5 checks: tool poisoning, instruction override, hidden content, exfiltration requests, metadata integrity
    Checked on every scan. Results in this category are published only after a person has verified them.
Supply Chainnot checked
  • Dependency manifests
    No manifest found
  • Lockfiles checked against OSV
    Nothing could be resolved to exact versions
  • MCP SDK version
    No MCP SDK declared in a manifest
Secrets & Credentials10.0
  • 3 checks: credential harvesting, undeclared credential access, credentials sent over the network
    Checked on every scan. Results in this category are published only after a person has verified them.
  • Tools that read credentials
    Not seen in the traced code of 49 capabilities; 49 more call code the scanner could not follow, where it may happen
  • Environment variables
    35 capabilities read environment variables (often API keys)
  • Authentication declared
    Not checked: needs the live server's tools/list (a remote server declares how clients authenticate)
Behavior Transparency10.0
  • 3 checks: undeclared network access, undeclared file access, undeclared process execution
    Checked on every scan. Results in this category are published only after a person has verified them.
  • Tool descriptions present
    Every tool has a description the model and the user can read
  • Statically known names
    Every tool's name could be read from the code
  • Input schemas
    Not checked: needs the live server's tools/list (every tool declares an input schema)
  • Destructive tools annotated
    Not checked: needs the live server's tools/list (tools that write, delete or run commands carry destructivehint)

Dependencies with known vulnerabilities (0 in production)

No known vulnerabilities in the production dependencies that could be checked.

Past security advisories

Vulnerabilities published for this server itself, from the GitHub Advisory Database.

No security advisories have been published for this server in the GitHub Advisory Database.

How it runs

Where it runsOn your machine, started by your MCP client from this repository or its package
Transportstdio
Sign-innot checked needs the live server
Servers in the code1 (ads-mcp)

The project's own security

Security policynone no SECURITY.md in the repository: report issues privately through GitHub if it is enabled
Past advisoriesnone in the GitHub Advisory Database
Last push2026-11-13
Signed releasesnot checked yet

Where it is published

Listed in1 catalog (github_search)
LicenseMIT
Created2026-10-01

Attack map

How the server is built and where its risky tools lead: servers, their tools, what the tools' code can do, and the traced route from a declared risky tool's argument to the operation it reaches. Click a node for details.

Request a scan or an audit

Tell us about your server. We reply within 5 working days.

What do you need? *

We use these details only to answer you.